Leaky coaxial cable 1 1/4″, radiation mode, FRNC Jacket

Leaky coaxial cable 1 1/4″, radiation mode, FRNC Jacket

Mechanical Data

Parameter Value
Cable Dimension (inch) 1 1/4
Tensile Strength (N) 2500
Min. Bending Radius – Single bend (mm) 300
Min. Bending Radius – Multiple bend (mm) 600
Minimum Distance to Wall (mm) 50
Recommended Hanger Spacing (m) 1.0

Electrical Data

Parameter Value
Impedance (Ω) 50
Relative Velocity of Propagation (%) 89
Capacitance (pF/m) 75
Insulation Resistance (MΩ x km) ≥5000
Insulation Voltage (V) 10000
Jacket Spark Test Voltage (V) 10000
Operating Frequency Band 75MHz to 2700 MHz
Optimum Operating Frequency Band 700MHz to 2700MHz
Stop Band 1085~1150MHz & 2170~2300MHz

VSWR Specifications

Frequency Range VSWR
75 MHz to 150 MHz ≤ 1.3
790 MHz to 960 MHz ≤ 1.3
1700 MHz to 2025 MHz ≤ 1.3
2100 MHz to 2170 MHz ≤ 1.3
2300 MHz to 2700 MHz ≤ 1.3

Performance Data

Frequency (MHz) Attenuation (dB/100m) Coupling loss 2m dB (50%) Coupling loss 2m dB (95%)
75 0.82 70 78
100 1.03 69 79
150 1.13 80 90
450 2.00 82 89
700 2.78 75 78
800 2.98 70 73
900 3.19 69 72
1800 5.35 65 68
2000 6.07 63 67
2200 6.59 63 66
2400 7.31 62 65
2600 7.70 62 66
2700 8.75 62 66

Remarks

Standard Conditions and Test Methods:

  • Attenuation at ambient temperature 20°C
  • Average power at ambient temperature 40°C and inner conductor temperature 100°C
  • Attenuation Test Method: IEC 61196-4
  • Attenuation Tolerance: ±5%
  • Coupling Loss Test Method: IEC 61196-4
  • Coupling Loss Tolerance: ±5 dB