Leaky coaxial cable 1 1/4″, radiation mode, FRNC Jacket
Mechanical Data
Parameter |
Value |
Cable Dimension (inch) |
1 1/4 |
Tensile Strength (N) |
2500 |
Min. Bending Radius – Single bend (mm) |
300 |
Min. Bending Radius – Multiple bend (mm) |
600 |
Minimum Distance to Wall (mm) |
50 |
Recommended Hanger Spacing (m) |
1.0 |
Electrical Data
Parameter |
Value |
Impedance (Ω) |
50 |
Relative Velocity of Propagation (%) |
89 |
Capacitance (pF/m) |
75 |
Insulation Resistance (MΩ x km) |
≥5000 |
Insulation Voltage (V) |
10000 |
Jacket Spark Test Voltage (V) |
10000 |
Operating Frequency Band |
75MHz to 2700 MHz |
Optimum Operating Frequency Band |
700MHz to 2700MHz |
Stop Band |
1085~1150MHz & 2170~2300MHz |
VSWR Specifications
Frequency Range |
VSWR |
75 MHz to 150 MHz |
≤ 1.3 |
790 MHz to 960 MHz |
≤ 1.3 |
1700 MHz to 2025 MHz |
≤ 1.3 |
2100 MHz to 2170 MHz |
≤ 1.3 |
2300 MHz to 2700 MHz |
≤ 1.3 |
Performance Data
Frequency (MHz) |
Attenuation (dB/100m) |
Coupling loss 2m dB (50%) |
Coupling loss 2m dB (95%) |
75 |
0.82 |
70 |
78 |
100 |
1.03 |
69 |
79 |
150 |
1.13 |
80 |
90 |
450 |
2.00 |
82 |
89 |
700 |
2.78 |
75 |
78 |
800 |
2.98 |
70 |
73 |
900 |
3.19 |
69 |
72 |
1800 |
5.35 |
65 |
68 |
2000 |
6.07 |
63 |
67 |
2200 |
6.59 |
63 |
66 |
2400 |
7.31 |
62 |
65 |
2600 |
7.70 |
62 |
66 |
2700 |
8.75 |
62 |
66 |
Remarks
Standard Conditions and Test Methods:
- Attenuation at ambient temperature 20°C
- Average power at ambient temperature 40°C and inner conductor temperature 100°C
- Attenuation Test Method: IEC 61196-4
- Attenuation Tolerance: ±5%
- Coupling Loss Test Method: IEC 61196-4