Leaky coaxial cable 1/2″, radiation mode, FRNC Jacket
Material
Component |
Specification |
Inner Conductor |
Copper Clad Aluminium Wire |
Dielectric |
Foam PE |
Outer Conductor |
Copper foil |
Jacket |
Flame retardant polyolefin, Black, Halogen free |
Mechanical Data
Parameter |
Value |
Cable Dimension (inch) |
1/2 |
Tensile Strength (N) |
1000 |
Min. Bending Radius – Single bend (mm) |
75 |
Min. Bending Radius – Multiple bend (mm) |
150 |
Minimum Distance to Wall (mm) |
50 |
Recommended Hanger Spacing (m) |
0.8 to 1.2 |
Electrical Data
Parameter |
Value |
Impedance (Ω) |
50 |
Relative Velocity of Propagation (%) |
86 |
Capacitance (pF/m) |
75 |
Insulation Resistance (MΩ x km) |
≥5000 |
Insulation Voltage (V) |
8000 |
Jacket Spark Test Voltage (V) |
6000 |
Operating Frequency Band |
75MHz to 2700 MHz |
Optimum Operating Frequency Band |
700MHz to 2700MHz |
Stop Band |
1085~1150MHz & 2170~2300MHz |
VSWR Specifications
Frequency Range |
VSWR |
75 MHz to 150 MHz |
≤ 1.4 |
800 MHz to 960 MHz |
≤ 1.4 |
1700 MHz to 2025 MHz |
≤ 1.4 |
2110MHz to 2170MHz |
≤ 1.4 |
2300MHz to 2700MHz |
≤ 1.4 |
Performance Data
Frequency (MHz) |
Attenuation (dB/100m) |
Coupling loss 2m dB (50%) |
Coupling loss 2m dB (95%) |
75 |
2.2 |
80 |
85 |
100 |
2.5 |
82 |
86 |
150 |
3.2 |
81 |
86 |
700 |
6.8 |
73 |
78 |
800 |
7.2 |
69 |
73 |
900 |
7.7 |
68 |
72 |
960 |
8.3 |
68 |
71 |
1800 |
11.8 |
65 |
68 |
1900 |
12.3 |
66 |
68 |
2000 |
12.8 |
67 |
70 |
2100 |
13.5 |
66 |
69 |
2400 |
15.5 |
63 |
67 |
2600 |
16.9 |
64 |
68 |
2620 |
17.8 |
64 |
68 |
2700 |
18.1 |
65 |
68 |
Remarks
Standard Conditions and Test Methods:
- Attenuation at ambient temperature 20°C
- Average power at ambient temperature 40°C and inner conductor temperature 100°C
- Attenuation Test Method: IEC 61196-4
- Attenuation Tolerance: ±5%
- Coupling Loss Test Method: IEC 61196-4
- Coupling Loss Tolerance: ±5 dB