Leaky coaxial cable 7/8″, radiation mode, FRNC Jacket

Leaky coaxial cable 7/8″, radiation mode, FRNC Jacket

Material

Component Specification
Inner Conductor Copper tube
Dielectric Foam PE
Outer Conductor Copper foil
Jacket Flame retardant polyolefin, Black, Halogen free

Mechanical Data

Parameter Value
Cable Dimension (inch) 7/8
Tensile Strength (N) 1300
Min. Bending Radius – Single bend (mm) 250
Min. Bending Radius – Multiple bend (mm) 500
Minimum Distance to Wall (mm) 50
Recommended Hanger Spacing (m) 0.8 to 1.2

Electrical Data

Parameter Value
Impedance (Ω) 50
Relative Velocity of Propagation (%) 89
Capacitance (pF/m) 75
Insulation Resistance (MΩ x km) ≥5000
Insulation Voltage (V) 10000
Jacket Spark Test Voltage (V) 8000
Operating Frequency Band 75MHz to 2700 MHz
Optimum Operating Frequency Band 700MHz to 2700MHz
Stop Band 1085 to 1150MHz & 2170 to 2300MHz

VSWR Specifications

Frequency Range VSWR
75 MHz to 150 MHz ≤ 1.3
800 MHz to 960 MHz ≤ 1.3
1700MHz to 2025MHz ≤ 1.3
2110MHz to 2170MHz ≤ 1.3
2300MHz to 2700MHz ≤ 1.3

Performance Data

Frequency (MHz) Attenuation (dB/100m) Coupling loss 2m dB (50%) Coupling loss 2m dB (95%)
75 1.34 70 79
100 1.54 70 81
150 1.85 78 89
450 2.45 79 86
700 4.02 73 77
800 4.12 70 73
900 4.32 69 72
1800 6.69 65 68
2000 7.41 63 66
2200 8.03 63 66
2400 8.44 62 65
2600 9.60 65 70
2700 10.92 62 66

Remarks

Standard Conditions and Test Methods:

  • Attenuation at ambient temperature 20°C
  • Average power at ambient temperature 40°C and inner conductor temperature 100°C
  • Attenuation Test Method: IEC 61196-4
  • Attenuation Tolerance: ±5%
  • Coupling Loss Test Method: IEC 61196-4
  • Coupling Loss Tolerance: ±5 dB
Scroll to Top