Flexible Coaxial Cable, corrugated copper, 50 Ω nominal, 1 5/8 in, black PE jacket
Coaxial Cable Specification
Material
- Inner Conductor: Corrugated copper tube
- Dielectric: Foam PE
- Outer Conductor: Corrugated copper (Annularly)
- Jacket: PE, Black, Halogen free
Mechanical Data
Parameter | Value |
---|---|
Cable Dimension (inch) | 1 5/8 |
Tensile Strength (N) | 3500 |
Min. Bending Radius (single) (mm) | 300 |
Min. Bending Radius (repeated) (mm) | 510 |
Number of Bends, Minimum (typical) | 15 (50) |
Recommended Hanger Spacing (m) | 1.2 |
Installation Temperature (℃) | -25 ~ +60 |
Operating Temperature (℃) | -40 ~ +85 |
Storage Temperature (℃) | -70 ~ +85 |
Electrical Data
Parameter | Value |
---|---|
Impedance (Ω) | 50 |
Relative Velocity of Propagation (%) | 88 |
Capacitance (pF/m) | 76 |
Inductance (μH/m) | 0.190 |
Maximum Operating Frequency (GHz) | 2.7 |
Cut-off Frequency (GHz) | 3.0 |
Peak Power Rating (kw) | 310 |
DC Breakdown Voltage (V) | 15000 |
Jacket Spark Test Voltage (V) | 10000 |
Return Loss (dB) | 800~1000MHz: ≤ -24 1700~2500MHz: ≤ -24 2500~2700MHz: ≤ -21 |
Attenuation and Power
Frequency (MHz) | Attenuation (dB/100m) | Average Power (kw) |
---|---|---|
100 | 0.67 | 18.0 |
200 | 0.98 | 11.8 |
300 | 1.23 | 9.46 |
400 | 1.45 | 8.02 |
450 | 1.53 | 7.45 |
800 | 2.12 | 5.33 |
900 | 2.28 | 4.97 |
1000 | 2.42 | 4.67 |
1800 | 3.45 | 3.26 |
2000 | 3.68 | 3.05 |
2200 | 3.91 | 2.87 |
2500 | 4.24 | 2.64 |
2700 | 4.64 | 2.42 |
Standard Conditions:
- Attenuation at ambient temperature 20°C
- Average power at ambient temperature 40°C and inner conductor temperature 100°C
- Maximum attenuation value shall be 105% of the nominal attenuation value