Flexible Coaxial Cable, corrugated copper, 50 Ω nominal, 1 5/8 in, black PE jacket

Flexible Coaxial Cable, corrugated copper, 50 Ω nominal, 1 5/8 in, black PE jacket

Coaxial Cable Specification

Material

  • Inner Conductor: Corrugated copper tube
  • Dielectric: Foam PE
  • Outer Conductor: Corrugated copper (Annularly)
  • Jacket: PE, Black, Halogen free

Mechanical Data

Parameter Value
Cable Dimension (inch) 1 5/8
Tensile Strength (N) 3500
Min. Bending Radius (single) (mm) 300
Min. Bending Radius (repeated) (mm) 510
Number of Bends, Minimum (typical) 15 (50)
Recommended Hanger Spacing (m) 1.2
Installation Temperature (℃) -25 ~ +60
Operating Temperature (℃) -40 ~ +85
Storage Temperature (℃) -70 ~ +85

Electrical Data

Parameter Value
Impedance (Ω) 50
Relative Velocity of Propagation (%) 88
Capacitance (pF/m) 76
Inductance (μH/m) 0.190
Maximum Operating Frequency (GHz) 2.7
Cut-off Frequency (GHz) 3.0
Peak Power Rating (kw) 310
DC Breakdown Voltage (V) 15000
Jacket Spark Test Voltage (V) 10000
Return Loss (dB) 800~1000MHz: ≤ -24
1700~2500MHz: ≤ -24
2500~2700MHz: ≤ -21

Attenuation and Power

Frequency (MHz) Attenuation (dB/100m) Average Power (kw)
100 0.67 18.0
200 0.98 11.8
300 1.23 9.46
400 1.45 8.02
450 1.53 7.45
800 2.12 5.33
900 2.28 4.97
1000 2.42 4.67
1800 3.45 3.26
2000 3.68 3.05
2200 3.91 2.87
2500 4.24 2.64
2700 4.64 2.42

Standard Conditions:

  • Attenuation at ambient temperature 20°C
  • Average power at ambient temperature 40°C and inner conductor temperature 100°C
  • Maximum attenuation value shall be 105% of the nominal attenuation value
Scroll to Top