Cable Management and Protection Solutions
In the complicated telecom system, there are many kinds of different cables deployed for both indoor and outdoor areas, to provide good signal passage. Accessories such as the hard conduit are created to protect the cables from damage and ensure long term usage quality.
In the complicated telecom system, there are many kinds of different cables deployed for both indoor and outdoor areas to provide good signal passage. Accessories such as hard conduits are created to protect the cables from damage and ensure long-term usage quality.
Hard Conduit
Hard conduits are tough and smooth, providing excellent resistance against rodent bites and heavy pressure in the short term. Due to their hardness, they come in limited lengths and require coupling during field installation.
Solutions
- PVC Conduit and Accessories: Short length supply, typically used on-site.
- HDPE Conduit and Accessories: Long length supply, ideal for long-distance transfer protection.
- IMC Conduit and Accessories: Short length supply, typically used on-site.
- Customized Galvanized Steel Conduit and Accessories: Custom dimensions or specifications as requested by customers.
PVC Conduit
The recommended environment temperature for PVC conduits is -15°C to +70°C, making them suitable for indoor use. They are available in various dimensions and colors.
Part Number | Ref. OD (mm) | Standard Length |
---|---|---|
RLHPP00-16-XX | 16 | 3m or 6m |
RLHPP00-20-XX | 20 | 3m or 6m |
RLHPP00-25-XX | 25 | 3m or 6m |
RLHPP00-32-XX | 32 | 3m or 6m |
RLHPP00-40-XX | 40 | 3m or 6m |
RLHPP00-50-XX | 50 | 3m or 6m |
RLHPP00-63-XX | 63 | 3m or 6m |
RLHPP00-75-XX | 75 | 3m or 6m |
RLHPP00-90-XX | 90 | 3m or 6m |
RLHPP00-110-XX | 110 | 3m or 6m |
Accessories Related
PV Conduit | Clamp | Coupler Right Angled | Coupler Straight |
---|---|---|---|
RLHPP00-16 | RLCCP-16 | RLRCP-16 | RLSCP-16 |
RLHPP00-20 | RLCCP-20 | RLRCP-20 | RLSCP-20 |
RLHPP00-25 | RLCCP-25 | RLRCP-25 | RLSCP-25 |
RLHPP00-32 | RLCCP-32 | RLRCP-32 | RLSCP-32 |
RLHPP00-40 | RLCCP-40 | RLRCP-40 | RLSCP-40 |
RLHPP00-50 | RLCCP-50 | RLRCP-50 | RLSCP-50 |
HDPE Conduit
HDPE conduits feature a permanent smooth Si coating on the inner layer, making them ideal for fiber cable protection. The normal length is 1000mm or more, facilitating easy fiber cable blowing. The recommended environment temperature is -40°C to +90°C, making them widely used in telecom projects.
Part Number | Ref. OD (mm) | Ref. ID (mm) | Standard Length (mm) |
---|---|---|---|
RLHSP-32-XX/XX | 32 | 26 | 1500/2000 |
RLHSP-34-XX/XX | 34 | 28 | 1500/2000 |
RLHSP-40-XX/XX | 40 | 33 | 1500/2000 |
RLHSP-46-XX/XX | 46 | 38 | 1500 |
RLHSP-50-XX/XX | 50 | 41 | 1500 |
RLHSP-63-XX/XX | 63 | 53 | 1000 |
Soft Conduit
Soft conduits can bend in a small radius, offering advantages in transport and deployment. In field installations, they can follow variational directions to avoid conflicts with equipment and walls.