Cable Management and Protection Solutions

In the complicated telecom system, there are many kinds of different cables deployed  for both indoor and outdoor areas, to provide good signal passage. Accessories such as the hard conduit are created to protect the cables from damage and ensure long term usage quality.

In the complicated telecom system, there are many kinds of different cables deployed for both indoor and outdoor areas to provide good signal passage. Accessories such as hard conduits are created to protect the cables from damage and ensure long-term usage quality.

Hard Conduit

Hard conduits are tough and smooth, providing excellent resistance against rodent bites and heavy pressure in the short term. Due to their hardness, they come in limited lengths and require coupling during field installation.

Solutions

  • PVC Conduit and Accessories: Short length supply, typically used on-site.
  • HDPE Conduit and Accessories: Long length supply, ideal for long-distance transfer protection.
  • IMC Conduit and Accessories: Short length supply, typically used on-site.
  • Customized Galvanized Steel Conduit and Accessories: Custom dimensions or specifications as requested by customers.

PVC Conduit

The recommended environment temperature for PVC conduits is -15°C to +70°C, making them suitable for indoor use. They are available in various dimensions and colors.

Part Number Ref. OD (mm) Standard Length
RLHPP00-16-XX163m or 6m
RLHPP00-20-XX203m or 6m
RLHPP00-25-XX253m or 6m
RLHPP00-32-XX323m or 6m
RLHPP00-40-XX403m or 6m
RLHPP00-50-XX503m or 6m
RLHPP00-63-XX633m or 6m
RLHPP00-75-XX753m or 6m
RLHPP00-90-XX903m or 6m
RLHPP00-110-XX1103m or 6m

Accessories Related

PV Conduit Clamp Coupler Right Angled Coupler Straight
RLHPP00-16RLCCP-16RLRCP-16RLSCP-16
RLHPP00-20RLCCP-20RLRCP-20RLSCP-20
RLHPP00-25RLCCP-25RLRCP-25RLSCP-25
RLHPP00-32RLCCP-32RLRCP-32RLSCP-32
RLHPP00-40RLCCP-40RLRCP-40RLSCP-40
RLHPP00-50RLCCP-50RLRCP-50RLSCP-50

HDPE Conduit

HDPE conduits feature a permanent smooth Si coating on the inner layer, making them ideal for fiber cable protection. The normal length is 1000mm or more, facilitating easy fiber cable blowing. The recommended environment temperature is -40°C to +90°C, making them widely used in telecom projects.

Part Number Ref. OD (mm) Ref. ID (mm) Standard Length (mm)
RLHSP-32-XX/XX32261500/2000
RLHSP-34-XX/XX34281500/2000
RLHSP-40-XX/XX40331500/2000
RLHSP-46-XX/XX46381500
RLHSP-50-XX/XX50411500
RLHSP-63-XX/XX63531000

Soft Conduit

Soft conduits can bend in a small radius, offering advantages in transport and deployment. In field installations, they can follow variational directions to avoid conflicts with equipment and walls.

CONTACT US

Professional OEM - Zoin Communication

Phone

Email

Scroll to Top